Media 000077406: Element Unspecified [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
8 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000077406
Media type
CTImageSeries
Object element or part
--
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Micro-CT volume
Creator
--
Date created
--
Date uploaded
May 12, 2019
FILE OBJECT DETAILS
File format(s)
image/tiff
File size
2.64 GB
Image width
1780
Image height
1197
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.039280
Y pixel spacing
0.039280
Z pixel spacing
0.039280
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
856
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Field Museum of Natural History, Chicago
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Serjoscha W. Evers provided access to these dataoriginally appearing in Foth et al. (2019) , the collection of which was funded by a NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
fmnh:amphibians and reptiles:216746
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Isch Neander
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1800
Voltage
80
Power
--
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000077406: Element Unspecified [CTImageSeries] [Etc]
(this media).
Processing Details
Creator
April Isch Neander
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000077406: Element Unspecified [CTImageSeries] [Etc] (this media)