Media 000078758: Skeleton
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000078758
Media type
Mesh
Object element or part
skeleton
Object represented
Object taxonomy
Hemiphractus helioi
Object organization
Side
--
Orientation
--
Short description
stl
Full description
Migrated MorphoSource 1 Media File Title: stl Migrated MorphoSource 1 Media Group Title: skeleton
Creator
--
Date created
--
Date uploaded
May 25, 2019

FILE OBJECT DETAILS Field Definitions

File name
AMNH-H-01342_2.stl
File format(s)
STL
File size
52.8 MB
Points
550567
Polygons
1106002
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
32.207, 40.124, 50.448
Centroid coordinates
-0.462, -1.535, 2.146
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Herpetology:A-1342 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
80
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000078747: Element Unspecified [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000078747: Element Unspecified [CTImageSeries] [Etc] was processed to create derived Media 000078758: Skeleton [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000078758: Skeleton [Mesh] [CT] (this media)