Media 000084005: Element Unspecified
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000084005
Media type
Mesh
Object element or part
--
Object taxonomy
Serripes groenlandicus
Side
Left
Orientation
--
Short description
FMNHIZ_12721_Cardiidae_Serripes_groenlandicus_(Mohr_1786)
Full description
Migrated MorphoSource 1 Media File Title: FMNHIZ_12721_Cardiidae_Serripes_groenlandicus_(Mohr_1786) Migrated MorphoSource 1 Media Group Title: shell
Creator
--
Date created
--
Date uploaded
August 01, 2019

FILE OBJECT DETAILS Field Definitions

File name
304.stl
File format(s)
STL
File size
71.9 MB
Points
753812
Polygons
1507662
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
26.267, 54.552, 45.120
Centroid coordinates
6.798, 8.227, 31.621
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Invertebrate Zoology:12721 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Katie S. Collins
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.131
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1700
Voltage
200
Power
0.04
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000084005: Element Unspecified [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Katie S. Collins
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000084005: Element Unspecified [Mesh] [Etc] (this media)