Media 000084005: Element Unspecified
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000084005: Element Unspecified
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000084005
Media type
Mesh
Object element or part
--
Object represented
Object taxonomy
Serripes groenlandicus
Object organization
Side
Left
Orientation
--
Short description
FMNHIZ_12721_Cardiidae_Serripes_groenlandicus_(Mohr_1786)
Full description
Migrated MorphoSource 1 Media File Title: FMNHIZ_12721_Cardiidae_Serripes_groenlandicus_(Mohr_1786) Migrated MorphoSource 1 Media Group Title: shell
Creator
--
Date created
--
Date uploaded
August 01, 2019
FILE OBJECT DETAILS Field Definitions
File name
304.stl
File format(s)
STL
File size
71.9 MB
Points
753812
Polygons
1507662
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
26.267, 54.552, 45.120
Centroid coordinates
6.798, 8.227, 31.621
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FMNH:Invertebrate Zoology:12721
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Katie S. Collins
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.131
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1700
Voltage
200
Power
0.04
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000084005: Element Unspecified [Mesh] [Etc] (this media).
Processing Details Field Definitions
Creator
Katie S. Collins
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000084005: Element Unspecified [Mesh] [Etc] (this media)