Media 000084020: Shell
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000084020
Media type
Mesh
Object element or part
shell
Object taxonomy
Palliolum striatum
Side
Left
Orientation
--
Short description
FMNHIZ_6140_Pectinidae_Palliolum_striatum_(Mueller_1776)
Full description
Migrated MorphoSource 1 Media File Title: FMNHIZ_6140_Pectinidae_Palliolum_striatum_(Mueller_1776) Migrated MorphoSource 1 Media Group Title: shell
Creator
--
Date created
--
Date uploaded
August 01, 2019

FILE OBJECT DETAILS Field Definitions

File name
3580.stl
File format(s)
STL
File size
2.82 MB
Points
29521
Polygons
59042
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
5.238, 14.728, 15.184
Centroid coordinates
-8.595, -0.138, -8.791
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Invertebrate Zoology:6140 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Katie S. Collins
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.131
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
2000
Voltage
150
Power
0.0225
Amperage
150
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000084020: Shell [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Katie S. Collins
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000084020: Shell [Mesh] [Etc] (this media)