Media 000097274: Head [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

GENERAL DETAILS

Media ID
000097274
Media type
CTImageSeries
Object element or part
head
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive \\r\\n\\r\\nMaisano\\r\\nBothrops: Scans of the head of Bothrops asper (FMNH 31162) for Dr. Jessie Maisano of The University of Texas at Austin and ATOL. Specimen scanned by Phillip Watson 9 September 2004. \\r\\n\\r\\n16bitrot: 1024x1024 16-bit TIFF images. II, 120 kV, 0.2 mA, no filter, empty container wedge, no offset, slice thickness 2 lines (= 0.1488 mm), S.O.D. 217 mm, 1200 views, 2 samples per view, inter-slice spacing 2 lines (= 0.1488 mm), field of reconstruction 55 mm (maximum field of view 71.11 mm), reconstruction offset 4579, reconstruction scale 1500. Acquired with 15 slices per rotation. Drift correction done by Susan Garlock on raw sinogram data using IDL routine “RK_SinoDeDrift” with default parameters. Images reconstructed with 34 degree rotation. Rotation correction processing done by Susan Garlock using IDL routine “DoRotationCorrection”. Images flipped because sample was mounted head down. Total slices = 540.\\r\\n
Creator
--
Date created
--
Date uploaded
December 03, 2019

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
518 MB
Image width
859
Image height
686
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.053700
Y pixel spacing
0.053700
Z pixel spacing
0.148800
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
540

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
IP holder
The Field Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EF-0334961, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: oUTCT provided access to these dataoriginally appearing in Gauthier et al., 2012, with data collection funded by NSF EF-0334961 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:amphibians and reptiles:31162 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Phillip Watson
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1200
Voltage
120
Power
--
Amperage
200
Surrounding material
empty container
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000097274: Head [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Phillip Watson
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000097274: Head [CTImageSeries] [Etc] (this media)