Media 000097822: Body [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000097822
Media type
CTImageSeries
File format(s)
image/jpeg
File size
180 MB
Object element or part
body
Side
--
Orientation
--
Short description
zipped jpg stack
Full description
Migrated MorphoSource 1 Media File Title: zipped jpg stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives Migrated MorphoSource 1 Media Group Description: Specimen Scan Symbol is A
Creator
--
Date created
--
Date uploaded
December 12, 2019
Image width
614
Image height
1041
Color space
--
Color depth
8
Compression
--
X pixel spacing
0.035528
Y pixel spacing
0.035528
Z pixel spacing
0.035528
Pixel spacing units
Mm
Number of images in set
4,166

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
--
IP holder
Texas A&M AgriLife Research
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701714; NSF DBI-1701665; oVert TCN; NSF DBI-1702442
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Texas A&M AgriLife Research provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tcwc:ichthyology:15238.03 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Adam Summers
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
1.6
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
5
Projections
1200
Voltage
60
Power
0.0066
Amperage
110
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000097822: Body [CTImageSeries] [CT] (this media).

Processing Details

Creator
Adam Summers
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource