Media 000098635: Head [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000098635
Media type
CTImageSeries
File format(s)
image/tiff
File size
759,855,110 bytes
Object element or part
head
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0741\\r\\n\\r\\nMaisano:\\r\\nZonosaurus: Scans of the head of the ornate plated lizard, Zonosaurus ornatus (YPM 12671, pet trade, no data, frozen specimen) for Jessie Maisano of The University of Texas at Austin. Specimen scanned by Matthew Colbert 27 August 2002. \\r\\n\\r\\n16bit: 1024x1024 16-bit TIFF images. II, 120 kV, 0.19 mA, no filter, empty mount wedge, no offset, slice thickness 2 lines (= 0.05317 mm), S.O.D. 77 mm, 1000 views, 2 samples per view, inter-slice spacing 2 lines (= 0.05317 mm), field of reconstruction 20.0 mm (maximum field of view 25.231908 mm), reconstruction offset 9000, reconstruction scale 1300. Acquired with 15 slices per rotation. Reconstructed off-center: x = -0.8, y = 1.4. Total slices = 540.
Creator
--
Date created
--
Date uploaded
January 13, 2020
Image width
947
Image height
942
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.01953
Y pixel spacing
0.01953
Z pixel spacing
0.05317
Pixel spacing units
Mm
Number of images in set
540

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Yale Peabody Museum
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
DEB-0132227, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: oUTCT provided access to these data , with data collection funded by NSF DEB-0132227 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ypm:vz:ypm herr 012671 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
2
Projections
1000
Voltage
120
Power
--
Amperage
190
Surrounding material
empty mount
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000098635: Head [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Matthew Colbert
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000098635: Head [CTImageSeries] [Etc] (this media)