Media 000100018: Body [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

GENERAL DETAILS

Media ID
000100018
Media type
CTImageSeries
Object element or part
body
Side
--
Orientation
--
Short description
zipped jpeg stack
Full description
Migrated MorphoSource 1 Media File Title: zipped jpeg stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives Migrated MorphoSource 1 Media Group Description: Specimen Scan Symbol is M cutout
Creator
--
Date created
--
Date uploaded
January 30, 2020

FILE OBJECT DETAILS

File origin
Local
File format(s)
image/jpeg
File size
164 MB
Image width
998
Image height
1032
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.035176
Y pixel spacing
0.035176
Z pixel spacing
0.035176
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
3,422

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
California Academy of Sciences
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
oVert TCN; NSF DBI-1701714; NSF DBI-1701665; NSF DBI-1701870
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: California Academy of Sciences provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object cas:ich:6811 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Link Morgan
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
1.17
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
4
Projections
800
Voltage
65
Power
0.007995
Amperage
123
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000100018: Body [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Link Morgan
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000100018: Body [CTImageSeries] [Etc] (this media)