Media 000100500: Whole Body [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000100500
Media type
CTImageSeries
Object element or part
whole body
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
February 05, 2020
FILE OBJECT DETAILS
File format(s)
image/tiff
File size
4.24 GB
Image width
1171
Image height
1187
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.055838
Y pixel spacing
0.055838
Z pixel spacing
0.055838
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,872
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, University of Michigan Museum of Zoology, Research Museums Center (University of Michigan)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
AMNH Dept of Mammalogy
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN; NSF DBI-1701713; NSF DBI-1701714
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: American Museum of Natural History provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
amnh:mammals:m-223965
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
University of Michigan Museum of Zoology, Research Museums Center (University of Michigan)
Creator
Ramon Nagesan, Shion Otsuka
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
250
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1601
Voltage
85
Power
0.017
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000100500: Whole Body [CTImageSeries] [CT]
(this media).
Processing Details
Creator
Ramon Nagesan, Shion Otsuka
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000100500: Whole Body [CTImageSeries] [CT] (this media)