Media 000101167: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000101167
Media type
Volumetric Image Series
Object element or part
Whole body
Object represented
Object taxonomy
Xenohyla truncata
Object organization
Side
--
Orientation
--
Short description
Tomogram stack (16bit tiffs)
Full description
Migrated MorphoSource 1 Media File Title: Tomogram stack (16bit tiffs) Migrated MorphoSource 1 Media Group Title: MicroCT and derivatives of ku:kuh:92190, Xenohyla truncata
Creator
--
Date created
--
Date uploaded
February 18, 2020

FILE OBJECT DETAILS Field Definitions

File name
Xenohyla-truncata-KU92190.zip
File format(s)
ZIP archive, TIFF
File size
4.25 GB
Image width
1421
Image height
967
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.021294
Y pixel spacing
0.021294
Z pixel spacing
0.021294
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,022

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Kansas
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object KU:KUH:92190 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200093
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1900
Voltage
70
Power
0.014
Amperage
200
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000101167: Whole Body [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000101167: Whole Body [CTImageSeries] [Etc] (this media)