Media 000101178: Skull [Mesh] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000101178
Media type
Mesh
Object element or part
Skull
Side
--
Orientation
--
Short description
mesh file (STL)
Full description
Migrated MorphoSource 1 Media File Title: mesh file (STL) Migrated MorphoSource 1 Media Group Title: MicroCT volume and derivatives of mcz:herp:a-137993, Werneria tandyi
Creator
--
Date created
--
Date uploaded
February 18, 2020
FILE OBJECT DETAILS
File format(s)
application/stl
File size
71.1 MB
Points
743,159
Polygons
1,491,076
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
14.687, 34.567, 47.492
Centroid coordinates
-0.665, -0.950, 0.646
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN; NSF DBI-1701714
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
mcz:herp:a-137993
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1800
Voltage
80
Power
0.012
Amperage
150
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000101177: Whole Body [CTImageSeries] [Etc]
.
Processing Details
Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000101177: Whole Body [CTImageSeries] [Etc]
was processed
to create
derived
Media 000101178: Skull [Mesh] [Etc]
(this media).
Processing Details
Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource

Media 000101178: Skull [Mesh] [Etc] (this media)