Media 000104303: Lumbar Vertebra 08
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000104303
Media type
Mesh
Object element or part
lumbar vertebra 08
Object represented
Object taxonomy
Scutisorex thori
Side
Midline
Orientation
--
Short description
FMNH 222613 Lumbar vertebra 08 - STL
Full description
Migrated MorphoSource 1 Media File Title: FMNH 222613 Lumbar vertebra 08 - STL Migrated MorphoSource 1 Media Group Title: FMNH 222613 Lumbar vertebrae - STL
Creator
--
Date created
--
Date uploaded
February 27, 2020

FILE OBJECT DETAILS Field Definitions

File name
Contour-Mesh-Of-L8--Smoothed--clean.stl
File format(s)
STL
File size
147 MB
Points
285441
Polygons
571890
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
5.554, 7.053, 4.709
Centroid coordinates
6.257, 5.999, 28.903
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1811627
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: SM Smith and KD Angielczyk provided access to these data with data collection funded by NSF DBI-1811627. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Mammals:222613 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
SM Smith
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1150
Voltage
70
Power
--
Amperage
230
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000104303: Lumbar Vertebra 08 [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
SM Smith
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000104303: Lumbar Vertebra 08 [Mesh] [Etc] (this media)