Media 000104779: Articulated Skull & Skeleton
Open Download
Type
CT Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000104779: Articulated Skull & Skeleton
Open Download
Type
CT Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Project
ยท Public
TAGS
GENERAL DETAILS
Media ID
000104779
Media type
CT Image Series
Object element or part
articulated skull & skeleton
Object represented
Object taxonomy
Ischyromys douglassi
Object organization
Side
--
Orientation
--
Short description
Ischyromys douglassi USNM 617532
Full description
Migrated MorphoSource 1 Media File Title: Ischyromys douglassi USNM 617532 Migrated MorphoSource 1 Media Group Title: Skull & skeleton of Ischyromys douglassi USNM 617532 Migrated MorphoSource 1 Media File Description: Please cite one or both of these papers if you download/use this specimen:\\r\\nAsher RJ, Smith MR, Rankin A, Emry, RJ. 2019. Congruence, fossils, and the evolutionary tree of rodents and lagomorphs. Royal Society Open Science 6: 190387. https://doi.org/10.7934/p2769\\r\\n\\r\\nRankin A, Emry RJ, Asher RJ. In Review. Anatomical sciuromorphy in "protrogomorph" rodents. Palaeontologica Electronica\\r\\n Migrated MorphoSource 1 Media Group Description: Please cite one or both of these papers if you download/use this specimen: Asher RJ, Smith MR, Rankin A, Emry, RJ. 2019. Congruence, fossils, and the evolutionary tree of rodents and lagomorphs. Royal Society Open Science 6: 190387. https://doi.org/10.7934/p2769 Rankin A, Emry RJ, Asher RJ. In Review. Anatomical sciuromorphy in "protrogomorph" rodents. Palaeontologica Electronica
Creator
--
Date created
--
Date uploaded
March 02, 2020
FILE OBJECT DETAILS
File format(s)
image/tiff
File size
1.47 GB
Image width
781
Image height
1003
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.113392
Y pixel spacing
0.113392
Z pixel spacing
0.113392
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,976
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Cambridge Biotomography Centre (University of Cambridge)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
United States National Museum (Smithsonian Institution)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
USNM:PAL:USNM PAL617532
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Cambridge Biotomography Centre (University of Cambridge)
Creator
RJ Asher
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
1
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
2366
Voltage
144
Power
--
Amperage
145
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000104779: Articulated Skull & Skeleton [CTImageSeries] [Etc] (this media).
Processing Details
Creator
RJ Asher
Date processed
--
Software
--
Description
--
Description attachment
None