Media 000109593: Sclerotic Ring [Mesh] [CT]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000109593
Media type
Mesh
File format(s)
application/ply
File size
4,619,626 bytes
Object element or part
sclerotic ring
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Micro-CT volume and derivative mesh files
Creator
Benson, Roger
Date created
--
Date uploaded
March 13, 2020
Points
66,301
Polygons
132,602
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6.14, 9.711, 7.762
Centroid coordinates
60.908, 16.089, 29.333
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
University of Michigan Museum of Zoology
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson
Publisher
--
Cite as
Roger Benson provided access to these data originally appearing in Bjarnason A, Benson RBJ. 2021. A 3D geometric morphometric dataset quantifying skeletal variation in birds. MorphoMuseuM. https://doi.org/10.18563/journal.m3.125, the collection of which was funded by the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ummz:birds:201948 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Computed Tomography in Earth & Environmental Sciences (CTEES) (University of Michigan)
Creator
Roger Benson, Tom Davies
Date
2021-02-07
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.354
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
1
Projections
1801
Voltage
130
Power
--
Amperage
290
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000109590: Skeleton [CTImageSeries] [CT] .

Processing Details

Creator
Roger Benson, Tom Davies
Date processed
2021-02-07
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000109590: Skeleton [CTImageSeries] [CT] was processed to create derived Media 000109593: Sclerotic Ring [Mesh] [CT] (this media).

Processing Details

Creator
TEMPO team
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000109593: Sclerotic Ring [Mesh] [CT] (this media)