Media 000111285: Tibiotarsus, Fibula
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000111285
Media type
Mesh
Object element or part
tibiotarsus, fibula
Object represented
Object taxonomy
Sclerurus mexicanus peruvianus
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Micro-CT volume and derivative mesh files
Creator
Benson, Roger
Date created
--
Date uploaded
March 17, 2020

FILE OBJECT DETAILS Field Definitions

File name
Sclerurus_mexicanus_FMNH_321715_tibiotarsus_right.ply
File format(s)
PLY
File size
30.9 MB
Points
431756
Polygons
864920
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
13813.199, 13929.439, 25362.101
Centroid coordinates
48397.555, 16346.620, 21661.954
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Field Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson
Publisher
--
Cite as
Roger Benson provided access to these data originally appearing in Bjarnason A, Benson RBJ. 2021. A 3D geometric morphometric dataset quantifying skeletal variation in birds. MorphoMuseuM. https://doi.org/10.18563/journal.m3.125, the collection of which was funded by the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Birds:321715 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Neander
Event date
February 07, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.25
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
2000
Voltage
150
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000111276: Skeleton [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
April Neander
Event date
February 07, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000111276: Skeleton [CTImageSeries] [CT] was processed to create derived Media 000111285: Tibiotarsus, Fibula [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
TEMPO team
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000111285: Tibiotarsus, Fibula [Mesh] [Etc] (this media)