Media 000113775: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000113775: Skull
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000113775
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
ANELYTROPSIS PAPILLOSUS
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 2034\\r\\n\\r\\nMaisano:\\r\\nanelyA: Scans of the skull of Anelytropsis papillosus [TCWC 72818] for Jessie Maisano of The University of Texas at Austin. Specimen scanned by Jessie Maisano 13 March 2009. Scanned in two halves and matched.\\r\\n\\r\\nscan parameters: Xradia. 4X objective, 55kV, 10W, 4s acquisition time, detector 10.6 mm, source -47.4 mm, XYZ [-426, 9907, -300], camera bin 2, angles ±95, 666 views, 0.15 mm glass filter, destreak applied. Reconstructed with center shift -1.5, beam hardening 1.8, theta 25, byte scaling [-0.02, 0.18], binning 1, ring correction applied. Averaged multiple reference (1 frame acquired every 44 views, each for 4s). Parameters same for AreaB except Y = 13909.9. Total slices = 1632. Voxels are 5.491 microns.\\r\\n
Creator
--
Date created
--
Date uploaded
March 26, 2020
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
1.09 GB
Image width
708
Image height
580
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.005491
Y pixel spacing
0.005491
Z pixel spacing
0.005491
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,632
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Biodiversity Research and Teaching Collections, Texas A&M University
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EF-0334961, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: oUTCT provided access to these dataoriginally appearing in Gauthier et al., 2012, with data collection funded by NSF EF-0334961 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
TCWC:Herpetology:72818
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Jessie Maisano
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
4
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
666
Voltage
55
Power
0.01
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000113775: Skull [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Jessie Maisano
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000113775: Skull [CTImageSeries] [Etc] (this media)