Media 000113792: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000113792
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Canis latrans
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0121\\r\\n\\r\\nScanned images of skulls and turbinates of Canis latrans (coyote) for Blaire Van Valkenburg and Ari Pollack of UCLA. Scanning done by Richard Ketcham on 8/9-8/12/99. Samples mounted in plexiglass cylinders, held in place with foam or clay. Coarse (skull) and fine (turbinate) scans done on different systems, due to size and resolution considerations. Only 16-bit TIFF image files archived.\\r\\n\\r\\nCoyote/female: Collection unknown, specimen #K 1225.\\r\\n\\r\\nSkull: RLS, 420 kV, 4.7 mA, aluminum filter, air wedge, 130% offset, gain 4, integration time 32 ms, slice thickness 2.0 mm, S.O.D. 752 mm, 1000 views, 4 rays averaged per view, 1 sample per view, inter-slice spacing 2.0 mm, field of reconstruction 94 mm, reconstruction offset 500, reconstruction scale 600. Images cropped to 512x375 pixels, to enable fitting them onto CD
Creator
--
Date created
--
Date uploaded
March 27, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
15.3 MB
Image width
512
Image height
375
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.180000
Y pixel spacing
0.180000
Z pixel spacing
2.000000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
97

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of California Los Angeles
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
IIS-9874781, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Blaire Van Valkenburgh and Tim Rowe provided access to these data , with data collection funded by NSF IIS-9874781 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ucla:1225 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
1000
Voltage
420
Power
--
Amperage
4700
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000113792: Skull [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000113792: Skull [CTImageSeries] [Etc] (this media)