Media 000113960: Turbinates
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
· Public
Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000113960
Media type
Volumetric Image Series
Object element or part
turbinates
Object represented
Object taxonomy
Canis lupus familiaris
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 3371\\r\\n\\r\\nVanValkenburgh:\\r\\ncafaturbs30539: Scans of the turbinates of Canis familiaris (LACM 30539) for Blaire VanValkenburgh of the University of California Los Angeles. Specimen scanned by Matthew Colbert 27 June 2014. \\r\\n\\r\\n16bit: Scan parameters: NSI scanner. Feinfocus source, high power, 190 kV, 0.12 mA, no filter, Perkin Elmer detector, 0.5 pF gain, 2 fps (499.893 ms integration time), no binning, no flip, source to object 200.857 mm, source to detector 1000 mm, continuous CT scan, no frames averaged, 0 skip frames, 3600 projections, 6 gain calibrations, 15 mm calibration phantom, data range [-4, 75] (rescaled from NSI default), beam-hardening correction = 0.5. Voxel size = 0.0633 mm. Total slices = 1934.\\r\\n
Creator
--
Date created
--
Date uploaded
April 01, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
4.74 GB
Image width
1533
Image height
1124
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.063300
Y pixel spacing
0.063300
Z pixel spacing
0.063300
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,934

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Natural History Museum of Los Angeles County
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On Any Repository
Funding attribution
IOS-1119768, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Blaire Van Valkenburgh provided access to these data , with data collection funded by NSF IOS-1119768 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object LACM:Mammals:30539 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
3600
Voltage
190
Power
--
Amperage
120
Surrounding material
0.5 pF gain
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000113960: Turbinates [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000113960: Turbinates [CTImageSeries] [Etc] (this media)