Media 000114058: Turbinates
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
· Public
Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000114058
Media type
Volumetric Image Series
Object element or part
turbinates
Object represented
Object taxonomy
Hyaena hyaena
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 2049\\r\\n\\r\\nVan Valkenburgh:\\r\\nhyaMT: Scans of the turbinates of a male Hyaena hyaena (USNM 182034 Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Hyaena_hyaena/
Creator
--
Date created
--
Date uploaded
April 03, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
642 MB
Image width
1024
Image height
1024
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.070000
Y pixel spacing
0.070000
Z pixel spacing
0.250000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
453

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
Smithsonian Institution, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
IOB-0517748, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Blaire Van Valkenburgh provided access to these data , with data collection funded by NSF IOB-0517748 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:MAMM:USNM 182034 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
1
Projections
1000
Voltage
450
Power
--
Amperage
1300
Surrounding material
gain
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000114058: Turbinates [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource