Media 000114063: Turbinates
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
· Public
Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000114063
Media type
Volumetric Image Series
Object element or part
turbinates
Object represented
Object taxonomy
Leopardus pardalis
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0392\\r\\n\\r\\nTheodor:\\r\\nleopardM: Scans of the turbinates of a male Leopardus pardalis mearnsi (LACM 25127, Costa Rica, Guanacaste Prov., San Juan de Santa Cruz, 0-1806 U.S.A.C.R. 960-360-95-50, 30 April 1963). Scanned for Dr. Jessica Theodor of University of California at Los Angeles in collaboration with Dr. Timothy Rowe, Department of Geological Sciences, University of Texas at Austin. 16bit uncorrected scans on Archive 0391. \\r\\n\\r\\n\\r\\nOriginal scan parameters: II, 150 kV, 0.16 mA, no filter, empty mount wedge, 160% offset, slice thickness 3 lines (= 0.154 mm), S.O.D. 90 mm, 1200 views, 6 samples per view, interslice spacing 3 lines (= 0.154 mm), field of reconstruction 33 mm (maximum field of view = 45.677021), reconstruction offset 485, reconstruction scale 80, x = 0.2, y = 2.0. Scanned in three-slice mode. \\r\\n\\r\\nturb/warpcorr: The above images modified with IDL software “Unwarp v.1.0” written by Dr. Richard Ketcham to correct for radial distortion of images introduced by ACTIS scanning software. Corrected images are now 1034 pixels by 1034 pixels, resulting in a revised field of reconstruction of 33.3322 mm.\\r\\n\\n\\nRelated URL: http://digimorph.org/specimens/Leopardus_pardalis/male/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Leopardus_pardalis/male/
Creator
--
Date created
--
Date uploaded
April 03, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
115 MB
Image width
1034
Image height
1034
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.032000
Y pixel spacing
0.032000
Z pixel spacing
0.154000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
117

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Natural History Museum of Los Angeles County
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On Any Repository
Funding attribution
IIS-9874781, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Blaire Van Valkenburgh provided access to these data , with data collection funded by NSF IIS-9874781 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object LACM:Mammals:25127 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
6
Projections
1200
Voltage
150
Power
--
Amperage
160
Surrounding material
empty mount
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000114063: Turbinates [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000114063: Turbinates [CTImageSeries] [Etc] (this media)