Media 000114201: Turbinates [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
GENERAL DETAILS
Media ID
000114201
Media type
CTImageSeries
Object element or part
turbinates
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0353\\r\\n\\r\\nTheodor:\\r\\n The images below were modified with IDL software “Unwarp v.1.0” written by Dr. Richard Ketcham to correct for radial distortion of images introduced by ACTIS scanning software. \\r\\n\\r\\n\\r\\nUrocyonM: Corrected scans of turbinates of Urocyon cinereoargentaeus scottii (male, UCLA 6928, location 14 mi. E. of Fort Lowell, Arizona), for Jessica Theodor and Blaire Van Valkenburgh of the Department of Organismic Biology, Ecology and Evolution, UCLA, in collaboration with Timothy Rowe of the University of Texas Department of Geological Sciences. \\r\\n\\r\\nOriginal scan parameters: Scanned by Matthew Colbert on 19 October 2000. 1024x1024 16-bit TIFF images. II, 120 kV, 0.2 mA, no filter, empty mount wedge, 160% offset, slice thickness 7 lines (= 0.240 mm), S.O.D. 50 mm, 1200 views, 6 samples per view, inter-slice spacing 7 lines (= 0.240 mm), field of reconstruction 19 mm, reconstruction offset 400, reconstruction scale 40. Scanned in three-slice mode.\\r\\n\\r\\nturb/warpcorr: corrected 16bit images. Images are now 1032 X 1032 pixels, with a field of reconstruction = 19.15 mm.\\r\\n\\n\\nRelated URL: http://www.digimorph.org/specimens/Urocyon_cinereoargenteus/male/ Migrated MorphoSource 1 Media Group Description: Related URL: http://www.digimorph.org/specimens/Urocyon_cinereoargenteus/male/
Creator
--
Date created
--
Date uploaded
April 06, 2020
FILE OBJECT DETAILS
File format(s)
image/tiff
File size
1.84 GB
Image width
1023
Image height
950
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.019000
Y pixel spacing
0.019000
Z pixel spacing
0.240000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,400
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
University of California Los Angeles
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
IIS-9874781, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Blaire Van Valkenburgh provided access to these data , with data collection funded by NSF IIS-9874781 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ucla:mammals:6928
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
6
Projections
1200
Voltage
120
Power
--
Amperage
200
Surrounding material
empty mount
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000114201: Turbinates [CTImageSeries] [Etc]
(this media).
Processing Details
Creator
Matthew Colbert
Date processed
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000114201: Turbinates [CTImageSeries] [Etc] (this media)