Media 000114484: Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000114484: Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000114484
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Protopterus annectens
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0330\\r\\n\\r\\nBell:\\r\\nlungfish: Scans of the head of a lungfish (Protopterus annectens, TMM M-1129, pet trade) for Dr. Christopher Bell, Department of Geological Sciences, University of Texas, Austin. Specimen scanned partially frozen. Scanned by Richard Ketcham and Matthew Colbert on 22 January, 2001. \\r\\n\\r\\n16bit: RLS, 420 kV, 1.8 mA, no filter, air wedge, 160% offset, gain 8, integration time 32 ms, slice thickness 0.5 mm, S.O.D. 626 mm, 1000 views, 4 rays averaged per view, 1 sample per view, inter-slice spacing 0.5 mm, field of reconstruction 94 mm, reconstruction offset 600, reconstruction scale 355. \\r\\n
Creator
--
Date created
--
Date uploaded
April 16, 2020
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
62.2 MB
Image width
479
Image height
434
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.180000
Y pixel spacing
0.180000
Z pixel spacing
0.500000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
275
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Chris Bell provided access to these data , with data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
tmm:m:1129
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS scanner with GE Titan X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert and Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
1000
Voltage
420
Power
--
Amperage
1800
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000114484: Head [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert and Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource