Media 000114486: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000114486
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Shinisaurus crocodilurus
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0235\\r\\n\\r\\nBell: \\r\\n Scans of the head of a juvenile Shinisaurus for Dr. Chris Bell of the University of Texas, Dept. Geological Sciences. Specimen preserved in alcohol, and donated from a private collection. Scanned by Matthew Colbert on 20-21 April, 2000.\\r\\n\\r\\n shini: original scanned images. II, 120 kV, 0.2 mA, no filter, alcohol in mount wedge, 160% offset, slice thickness 2 lines (= 0.029 mm), S.O.D. 25 mm, 2400 views, 3 samples per view, interslice spacing 2 lines (= 0.029 mm), field of reconstruction 12.5 mm, reconstruction offset 900, reconstruction scale 13. Scanned in three-slice mode. \\r\\n\\n\\nRelated URL: http://digimorph.org/specimens/Shinisaurus_crocodilurus/juvenile/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Shinisaurus_crocodilurus/juvenile/
Creator
--
Date created
--
Date uploaded
April 16, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
136 MB
Image width
477
Image height
441
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.024000
Y pixel spacing
0.024000
Z pixel spacing
0.029000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
516

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Natural History Collections
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Chris Bell provided access to these data , with data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tnhc:herpetology:62987 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
2400
Voltage
120
Power
--
Amperage
200
Surrounding material
alcohol in mount
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000114486: Head [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000114486: Head [CTImageSeries] [Etc] (this media)