Media 000114492: Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000114492: Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000114492
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Sphenodon punctatus
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0081\\r\\n\\r\\nBell/sphen\\r\\n\\r\\nScans of Sphenodon punctatus. Done for Dr. Chris Bell of UT DOGS. Sample represents an uncatalogued fluid-preserved head, from the Peabody Museum of Natural History at Yale University. Sample scanned in air, in cylinder with bubble wrap and some fluid on bottom.\\r\\n\\r\\nSpheno/8bit and 16bit: Original images. Scanning done by Richard Ketcham and Matthew Colbert on 2/19/99. Images 512x512 TIFF format, 8-bit or 16-bit grayscale.\\r\\n\\r\\nII, 120 kV, 0.267 mA, no filter, air wedge, 160% offset, slice width 0.225 mm, S.O.D. 126 mm, 1800 views, 2 samples per view, inter-slice spacing 0.15 mm, field of reconstruction 56 mm, reconstruction offset 450, reconstruction scale 75.\\r\\nSpecimen scanned in 3-slice mode, discarding every third slice.\\r\\n8-bit export parameters: level 2047, width 4095.\\r\\n\\n\\nRelated URL: http://digimorph.org/specimens/Sphenodon_punctatus/adult/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Sphenodon_punctatus/adult/
Creator
--
Date created
--
Date uploaded
April 16, 2020
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
114 MB
Image width
453
Image height
417
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.109000
Y pixel spacing
0.109000
Z pixel spacing
0.150000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
520
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Yale Peabody Museum
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Chris Bell provided access to these data , with data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
YPM:VZ:YPM HERR 009194
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert and Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1800
Voltage
120
Power
--
Amperage
267
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000114492: Head [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert and Richard Ketcham
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000114492: Head [CTImageSeries] [Etc] (this media)