Media 000114523: Head [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000114523
Media type
CTImageSeries
File format(s)
image/tiff
File size
75,662,592 bytes
Object element or part
head
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0229\\r\\n\\r\\nBell: \\r\\nAngolo: Corrected scans of Angolosaurus (CAS 206978). Scanned by Richard Ketcham on 3/28/2000. Image processing done to correct for levels shift in slices 271-402, method was to shift histograms based on grayscale levels of air and flesh. Image processing done by Richard Ketcham on 4/11/2000.\\r\\n\\r\\n16bit: Complete corrected data set (original images 1-270, corrected images 271-402). II, 100 kV, 0.24 mA, no filter, empty mount cylinder wedge, 160% offset, slice thickness 2 lines (= 0.053 mm), S.O.D. 46 mm, 1800 views, 2 samples per view, interslice spacing 2 lines (=0.053 mm), field of reconstruction 18 mm, reconstruction offset 500, reconstruction scale 20, reconstruction angle –5.57 degrees. Scanned in three-slice mode.\\r\\n\\n\\nRelated URL: http://digimorph.org/specimens/Angolosaurus_skoogi/adult/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Angolosaurus_skoogi/adult/
Creator
--
Date created
--
Date uploaded
April 16, 2020
Image width
409
Image height
337
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.035
Y pixel spacing
0.035
Z pixel spacing
0.053
Pixel spacing units
Mm
Number of images in set
402

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
California Academy of Sciences
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Chris Bell provided access to these data , with data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object cas:herp:206978 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Richard Ketcham
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
2
Projections
1800
Voltage
100
Power
--
Amperage
240
Surrounding material
empty mount
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000114523: Head [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Richard Ketcham
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource