Media 000114654: Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000114654: Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000114654
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Phrynosoma taurus
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0395\\r\\n\\r\\nRowe: \\r\\n Ptaurus: Scans of a gravid specimen of Phrynosoma taurus (WLH1081: Female. Mexico: Guerrero: Municipio Eduardo Neri. Zumpango del Rio, 1 km on SE side of old highway 95, take dirt road just N of a row of businesses along road, steep hillsides. Xeric thornscrub, acacia, opuntia, on a steep hillside deep in the base of an Acacia sp. plant, many branches surrounding it on steep, gravely, rocky, north facing\\r\\nhillside. Sitting up on legs in basking position, eyes closed on a clear, sunny\\r\\nday. UTM coordinates: 17, 39, 04 N: 99, 32, 17 W. 1100 m. 20 April 1999,\\r\\n17:30 hrs, collected by Wendy Hodges). Scanned for Dr. Timothy Rowe of the University of Texas Department of Geological Sciences and Wendy Hodges of the Zoology Department.\\r\\n\\r\\nhead: original scans. II, 150 kV, 0.16 mA, no filter, air wedge, 160% offset, slice thickness 2 lines (= 0.086 mm), S.O.D. 75 mm, 1200 views, 2 samples per view, interslice spacing 2 lines (=0.086 mm), field of reconstruction 32 mm (maximum field of view 38.06 mm), reconstruction offset 650, reconstruction scale 45. Scanned in three-slice mode.\\r\\nFile header not modified.\\r\\n\\r\\nhead/warpcorr: The above images modified with IDL software “Unwarp v.1.0” written by Dr. Richard Ketcham to correct for radial distortion of images introduced by ACTIS scanning software. Corrected images are now 518 pixels by 518 pixels, resulting in a revised field of reconstruction of 32.375 mm. \\r\\n\\n\\nRelated URL: http://digimorph.org/specimens/Phrynosoma_taurus/head/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Phrynosoma_taurus/head/
Creator
--
Date created
--
Date uploaded
April 21, 2020
FILE OBJECT DETAILS Field Definitions
File name
16bit.zip
File format(s)
ZIP archive, TIFF
File size
45 MB
Image width
428
Image height
335
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.063000
Y pixel spacing
0.063000
Z pixel spacing
0.086000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
255
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
IIS-9874781, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Tim Rowe and Wendy Hodges provided access to these data , with data collection funded by NSF IIS-9874781 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
l-wlh:1081
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1200
Voltage
150
Power
--
Amperage
160
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000114654: Head [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000114654: Head [CTImageSeries] [Etc] (this media)