Media 000114720: Element Unspecified [Image] [CT]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000114720
Media type
Image
File format(s)
image/tiff
File size
3,502,686,171 bytes
Object element or part
--
Side
NotApplicable
Orientation
--
Short description
DICOM TIFF of raw scan
Full description
Migrated MorphoSource 1 Media File Title: DICOM TIFF of raw scan Migrated MorphoSource 1 Media Group Title: Whole body micro-CT scan Migrated MorphoSource 1 Media File Description: 1997 x 1609 x 1012 (x y z)
Creator
--
Date created
--
Date uploaded
April 22, 2020
Image width
1997
Image height
1609
Color space
BlackIsZero
Color depth
8
Compression
Uncompressed
X pixel spacing
0.0173332
Y pixel spacing
0.0173332
Z pixel spacing
0.0173332
Pixel spacing units
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix nanotom m, SNSB X-ray facility (Bavarian State Collection of Zoology)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Mark D. Scherz
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Mark D. Scherz provided access to these dataScherz 2020 'Diamond frogs forever: A new species of Rhombophryne Boettger, 1880 (Microhylidae, Cophylinae) from Montagne d’Ambre National Park, north Madagascar' Zoosystematics and Evolution. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object zsm:76/2018 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix nanotom m
Device facility
SNSB X-ray facility (Bavarian State Collection of Zoology)
Creator
Mark D. Scherz
Date
2021-03-03
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.75
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
1
Projections
2440
Voltage
140
Power
--
Amperage
80
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000114720: Element Unspecified [Image] [CT] (this media).

Processing Details

Creator
Mark D. Scherz
Date processed
2021-03-03
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000114720: Element Unspecified [Image] [CT] (this media)