Media 000115097: Partial Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000115097
Media type
Volumetric Image Series
Object element or part
partial skull
Object represented
Object taxonomy
Paramacellodus sp.
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 1755\\r\\n\\r\\n\\r\\nMaisano:\\r\\nparam: Scans of a partial skull of Paramacellodus (DINO 14864) for Dr. Jessie Maisano of The University of Texas at Austin and ATOL. Specimen scanned by Matthew Colbert 18 September 2007. \\r\\n\\r\\n16bit: 1024x1024 16-bit TIFF images. II, 180 kV, 0.13 mA, intensity control on, high-power mode, no filter, air wedge, no offset, slice thickness 2 lines (= 0.02642 mm), S.O.D. 36 mm, 1400 views, 2 samples per view, inter-slice spacing 2 lines (= 0.02642 mm), field of reconstruction 12.5 mm (maximum field of view 12.59975 mm), reconstruction offset 4800, reconstruction scale 2450. Acquired with 19 slices per rotation and 15 slices per set. Ring-removal processing done by Rachel Racicot based on correction of raw sinogram data using IDL routine “RK_SinoRingProcSimul” with default parameters. Deleted last four duplicate slices of each rotation. Deleted first five and last fifteen blank slices of data set. Total final slices = 820.\\r\\n
Creator
--
Date created
--
Date uploaded
April 28, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
594 MB
Image width
915
Image height
479
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.012210
Y pixel spacing
0.012210
Z pixel spacing
0.026420
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
820

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
Dinosaur National Monument
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
Encouraged But Not Required
Funding attribution
EF-0334961, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: oUTCT provided access to these data originally appearing in Gauthier et al., 2012, with data collection funded by NSF EF-0334961 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dino:14864 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1400
Voltage
180
Power
--
Amperage
130
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000115097: Partial Skull [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000115097: Partial Skull [CTImageSeries] [CT] (this media)