Media 000115124: Skull [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000115124
Media type
CTImageSeries
File format(s)
image/tiff
File size
803,193,309 bytes
Object element or part
skull
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 1362 \\r\\n\\r\\nMaisano:\\r\\n Peltosaurus: Scans of a fossil skull of Peltosaurus granulosus (FMNH P-27072) for Jessie Maisano of The University of Texas at Austin and AToL. Specimen scanned by Matthew Colbert 7 December 2005. \\r\\n\\r\\n16bitrot: 1024x1024 16-bit TIFF images. II, 180 kV, 0.133 mA, no filter, air wedge, no offset, slice thickness 2 lines (= 0.05865 mm), S.O.D. 86 mm, 1400 views, 2 samples per view, inter-slice spacing 2 lines (= 0.05865 mm), field of reconstruction 28 mm (maximum field of view 28.18174 mm), reconstruction offset 7400, scanner scale 2700, reconstruction scale 600. Acquired with 15 slices per rotation. Drift- and ring-removal processing done by Jessie Maisano based on correction of raw sinogram data using IDL routines “RK_SinoDeDrift” and “RK_SinoRingProcSimul,” both with default parameters. Rotation correction processing done using IDL program “DoRotationCorrection.” Total slices = 825.\\r\\n\\n\\nRelated URL: http://digimorph.org/specimens/Peltosaurus_granulosus/FMNH27072/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Peltosaurus_granulosus/FMNH27072/
Creator
--
Date created
--
Date uploaded
April 28, 2020
Image width
942
Image height
621
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.02734
Y pixel spacing
0.02734
Z pixel spacing
0.05865
Pixel spacing units
Mm
Number of images in set
825

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
The Field Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EF-0334961, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: oUTCT provided access to these dataoriginally appearing in Gauthier et al., 2012, with data collection funded by NSF EF-0334961 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:P-27072 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
2
Projections
1400
Voltage
180
Power
--
Amperage
133
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000115124: Skull [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Matthew Colbert
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000115124: Skull [CTImageSeries] [Etc] (this media)