Media 000115607: Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000115607: Head
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000115607
Media type
Volumetric Image Series
Object element or part
head
Object represented
Object taxonomy
Thorius minutissimus
Object organization
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 3123\\r\\n\\r\\nHanken:\\r\\n23011A: Scans of the head of Thorius minutissimus (IBH 23011) for James Hanken of Harvard University. Specimen scanned by Jessie Maisano 12 December 2013. \\r\\n\\r\\nscan parameters: Xradia. 4X objective, 70kV, 10W, 1s acquisition time, detector 14.3 mm, source -37 mm, XYZ [-890, 40981, 184], camera bin 2, angles ±180, 1081 views, no filter, dithering, no sample drift correction. End reference (45 frames, each for 1s). Reconstructed with center shift 1, beam hardening 2.4, theta -16, byte scaling [-50, 850], binning 1, recon filter smooth (kernel size = 0.7). Total slices = 952. Voxels are 4.86 microns.\\r\\n\\n\\nRelated URL: http://digimorph.org/specimens/Thorius_minutissimus/whole/ Migrated MorphoSource 1 Media Group Description: Related URL: http://digimorph.org/specimens/Thorius_minutissimus/whole/
Creator
--
Date created
--
Date uploaded
May 05, 2020
FILE OBJECT DETAILS Field Definitions
File name
head.zip
File format(s)
ZIP archive, TIFF
File size
683 MB
Image width
670
Image height
652
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.004860
Y pixel spacing
0.004860
Z pixel spacing
0.004860
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
952
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Colección Nacional de Anfibios y Reptiles, Mexico City
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: James Hanken and David Wake provided access to these data , with data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
ibunam:cnar:23011
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Jessie Maisano
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
1081
Voltage
70
Power
0.01
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000115607: Head [CTImageSeries] [Etc] (this media).
Processing Details Field Definitions
Creator
Jessie Maisano
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000115607: Head [CTImageSeries] [Etc] (this media)