Media 000116794: Element Unspecified
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000116794
Media type
Volumetric Image Series
Object element or part
--
Object represented
Side
--
Orientation
--
Short description
zipped jpeg stack
Full description
Migrated MorphoSource 1 Media File Title: zipped jpeg stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives Migrated MorphoSource 1 Media Group Description: Specimen Scan Symbol is n/a
Creator
--
Date created
--
Date uploaded
May 28, 2020

FILE OBJECT DETAILS Field Definitions

File name
Ouvc_H_10866_head.zip
File format(s)
ZIP archive, JPEG
File size
494 MB
Image width
1255
Image height
1301
Color space
YCbCr
Color depth
8
Compression
JPEG
X pixel spacing
0.035001
Y pixel spacing
0.035001
Z pixel spacing
0.035001
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,188

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Ohio Univeristy Vertebrate Collection
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701665
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Ohio Univeristy Vertebrate Collection provided access to these data , the collection of which was funded by NSF DBI-1701665.. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ouvc:h:10866 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Jasmine Croghan
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1.015
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
4
Projections
800
Voltage
80
Power
0.0072
Amperage
90
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000116794: Element Unspecified [CTImageSeries] [Etc] (this media).

Processing Details Field Definitions

Creator
Jasmine Croghan
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000116794: Element Unspecified [CTImageSeries] [Etc] (this media)