Media 000126114: Stained Syrinx [CTImageSeries] [Etc]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000126114
Media type
CTImageSeries
File format(s)
image/tiff
File size
1,907,063,800 bytes
Object element or part
stained syrinx
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive\\r\\n\\r\\nClarke: \\r\\nFulica_PTA_: Scan of a syrinx of an Amercian coot stained with phosphotungstic acid solution for ~3 days 21 hours and 32 minutes following a 0.5 % iodine-ethyl alchol solution stain of ~7 days 1 hour and 55 minutes (Fulica americana
Creator
--
Date created
--
Date uploaded
July 15, 2020
Image width
828
Image height
911
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.0348
Y pixel spacing
0.0348
Z pixel spacing
0.0348
Pixel spacing units
Mm
Number of images in set
1,677

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging N/R, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
Texas Memorial Museum
Funding attribution
Gordon and Betty Moore Foundation Grant 4498, NSF DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Julia Clarke provided access to these data , with data collection funded by the Gordon and Betty Moore Foundation Grant 4498 and data upload to MorphoSource funded by NSF DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:m:16916 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging N/R
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
1
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
none
Projections
1200
Voltage
120
Power
--
Amperage
175
Surrounding material
0.25 pF gain
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000126114: Stained Syrinx [CTImageSeries] [Etc] (this media).

Processing Details

Creator
Matthew Colbert
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000126114: Stained Syrinx [CTImageSeries] [Etc] (this media)