Media 000126156: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000126156
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object organization
Side
--
Orientation
--
Short description
Tomogram Stack (16 bit tiffs)
Full description
Migrated MorphoSource 1 Media File Title: Tomogram Stack (16 bit tiffs) Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives of JZCBU:154
Creator
--
Date created
--
Date uploaded
July 16, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
1.8 GB
Image width
990
Image height
990
Color space
BlackIsZero
Color depth
16
Compression
PackBits
X pixel spacing
0.004594
Y pixel spacing
0.004594
Z pixel spacing
0.004594
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,477

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x, AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:jzcbu:154 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x
Device facility
AMNH Microscopy and Imaging Facility (MIF) (American Museum of Natural History)
Creator
Morgan Hill
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.75
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
4
Projections
1500
Voltage
60
Power
0.013800000000000002
Amperage
230
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000126156: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Morgan Hill
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000126156: Whole Body [CTImageSeries] [CT] (this media)