Media 000126217: Vestibular Apparatus
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000126217
Media type
Mesh
Object element or part
Vestibular apparatus
Object represented
Object taxonomy
Hispanopithecus laietanus
Side
Right
Orientation
--
Short description
IPS18000
Full description
Migrated MorphoSource 1 Media File Title: IPS18000 Migrated MorphoSource 1 Media Group Title: Partial cranium and skeleton
Creator
--
Date created
--
Date uploaded
July 18, 2020

FILE OBJECT DETAILS Field Definitions

File name
IPS18000_vest_PNAS.ply
File format(s)
PLY
File size
479 KB
Points
12892
Polygons
25789
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
7.728, 8.388, 9.208
Centroid coordinates
-9.342, -2.894, -4.117
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
X-Ray Engineering (XRE bvba, Ghent, Belgium) HECTOR (custom installation), University of Ghent Centre for X-ray Tomography (Ghent University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Urciuoli Alessandro and colleagues provided access to these dataoriginally appearing in Urciuoli et al., 2021.. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object ips:18000 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
X-Ray Engineering (XRE bvba, Ghent, Belgium) HECTOR (custom installation)
Device facility
University of Ghent Centre for X-ray Tomography (Ghent University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
125
Power
--
Amperage
120
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000126217: Vestibular Apparatus [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000126217: Vestibular Apparatus [Mesh] [CT] (this media)