Media 000154249: Head
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000154249
Media type
Mesh
Object element or part
head
Object represented
Object taxonomy
Pletholax gracilis
Object organization
Side
--
Orientation
--
Short description
3D mesh of skull
Full description
Migrated MorphoSource 1 Media File Title: 3D mesh of skull Migrated MorphoSource 1 Media Group Title: 3D mesh model from HRXCT scan
Creator
--
Date created
--
Date uploaded
August 05, 2020

FILE OBJECT DETAILS Field Definitions

File name
Pletholax_Gracilis_187676A.ply
File format(s)
PLY
File size
36 MB
Points
499772
Polygons
999682
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
2.569, 2.361, 7.930
Centroid coordinates
2.478, 1.916, 4.486
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
DEB-0844523, DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Aaron Bauer provided access to these data , with data collection funded by NSF DEB-0844523 and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MCZ:Herp:R-187676 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia microXCT-400
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Jessie Maisano
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
577
Voltage
90
Power
0.01
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000103851: Head [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Jessie Maisano
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000103851: Head [CTImageSeries] [Etc] was processed to create derived Media 000154249: Head [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Jessie Maisano
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000154249: Head [Mesh] [Etc] (this media)