Media 000157595: Labyrinth [Mesh] [CT]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000157595
Media type
Mesh
Object element or part
labyrinth
Side
Left
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Micro-CT volume and derivative mesh files
Creator
Neenan, James
Date created
--
Date uploaded
August 12, 2020

FILE OBJECT DETAILS

File format(s)
application/stl
File size
1.26 MB
Points
13,209
Polygons
26,438
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
9.876, 8.508, 6.549
Centroid coordinates
10.689, 21.851, 25.965
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Natural History Museum, London (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson
Publisher
European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson
Cite as
Roger Benson provided access to these data, originally appearing in Choiniere et al. (2021) Evolution of vision and hearing modalities in theropod dinosaurs, Science, the collection of which was funded by the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nhmuk:S/1974.25.42 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
Creator
Roger Benson, Tom Davies
Date
May 10, 2021
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.354
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
1801
Voltage
90
Power
--
Amperage
333
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000157594: Element Unspecified [CTImageSeries] [CT] .

Processing Details

Creator
Roger Benson, Tom Davies
Date processed
May 10, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000157594: Element Unspecified [CTImageSeries] [CT] was processed to create derived Media 000157595: Labyrinth [Mesh] [CT] (this media).

Processing Details

Creator
Roger Benson, Tom Davies
Date processed
May 05, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000157595: Labyrinth [Mesh] [CT] (this media)