Media 000159260: Skull
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000159260
Media type
Mesh
Object element or part
skull
Object represented
Object taxonomy
Gerrhosaurus flavigularis
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
September 09, 2020

FILE OBJECT DETAILS Field Definitions

File name
UF-H-90238-head.obj
File format(s)
OBJ
File size
188 MB
Points
1045679
Polygons
2126541
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
17.983, 17.022, 34.804
Centroid coordinates
-0.080, -0.385, -0.500
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN; NSF DBI-1701714
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Florida Museum of Natural History, University of Florida provided access to these data provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:90238 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
4
Projections
1600
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000159259: Head [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000159259: Head [CTImageSeries] [Etc] was processed to create derived Media 000159260: Skull [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000159260: Skull [Mesh] [CT] (this media)