Media 000159383: R Mandible With P4 And M1 2 Lower [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000159383
Media type
CTImageSeries
Object element or part
R mandible with p4 and m1-2 lower
Side
Right
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: volume, mesh, ref photo Migrated MorphoSource 1 Media File Description: chiral-correct tif stack
Creator
--
Date created
--
Date uploaded
September 15, 2020

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
43.2 MB
Image width
248
Image height
289
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.013471
Y pixel spacing
0.013471
Z pixel spacing
0.013471
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
500

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Download permission
Publish with Restricted Download
IP holder
Duke Lemur Center
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dpc:8825 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Hesham Sallam
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000159383: R Mandible With P4 And M1 2 Lower [CTImageSeries] [CT] (this media).

Processing Details

Creator
Hesham Sallam
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000159383: R Mandible With P4 And M1 2 Lower [CTImageSeries] [CT] (this media)