Media 000162089: Dentary
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000162089
Media type
Volumetric Image Series
Object element or part
dentary
Object represented
Object taxonomy
Dastilbe elongatus
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: Synchrotron micro-CT volume
Creator
--
Date created
--
Date uploaded
September 29, 2020

FILE OBJECT DETAILS Field Definitions

File name
Dastilbe-elongatus_0.357_NHMUK-P63381_114230_pag_16bit.zip
File format(s)
ZIP archive, TIFF
File size
3.02 GB
Image width
1587
Image height
1700
Color space
BlackIsZero
Color depth
8
Compression
PackBits
X pixel spacing
0.357000
Y pixel spacing
0.357000
Z pixel spacing
0.357000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,089

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Diamond Manchester Imaging Branchline (I13-2), I13: X-ray Imaging and Coherence (Diamond Light Source Ltd)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
the Leverhulme research project grant (RPG-2016-168) to Roger Benson
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Donald Davesne, Armin Schmitt, Vincent Fernandez, Roger Benson, Sophie Sanchez provided access to these dataoriginally appearing in … , the collection of which was funded by Leverhulme research project grant (RPG-2016-168). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nhmuk:pal:PV P 63381 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Diamond Manchester Imaging Branchline (I13-2)
Device facility
I13: X-ray Imaging and Coherence (Diamond Light Source Ltd)
Creator
Malte Storm, Vincent Fernandez, Roger Benson, Donald Davesne, Armin Schmitt, Marie-Christine Zdora
Event date
May 26, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000162089: Dentary [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Malte Storm, Vincent Fernandez, Roger Benson, Donald Davesne, Armin Schmitt, Marie-Christine Zdora
Event date
May 26, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000162089: Dentary [CTImageSeries] [CT] (this media)