Media 000162123: Whole Body
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000162123
Media type
Mesh
Object element or part
Whole body
Object represented
Object taxonomy
Arenophryne rotunda
Object organization
Side
--
Orientation
--
Short description
Skeleton mesh
Full description
Migrated MorphoSource 1 Media File Title: Skeleton mesh Migrated MorphoSource 1 Media Group Title: CT scan of AMNH106749 Arenophryne rotunda
Creator
--
Date created
--
Date uploaded
September 29, 2020

FILE OBJECT DETAILS Field Definitions

File name
Arenophryne-rotunda-AMNH106749_skel.stl
File format(s)
STL
File size
29.7 MB
Points
310758
Polygons
621930
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
5.673, 16.743, 24.216
Centroid coordinates
-0.298, -2.388, -3.638
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Herpetology:A-106749 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
2000
Voltage
70
Power
0.014
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000100591: Whole Body [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000100591: Whole Body [CTImageSeries] [Etc] was processed to create derived Media 000162123: Whole Body [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Ed Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000162123: Whole Body [Mesh] [Etc] (this media)