GENERAL DETAILS Field Definitions

Media ID
000162129
Media type
Mesh
Object element or part
--
Object represented
Object taxonomy
Asterophrys turpicola
Object organization
Side
--
Orientation
--
Short description
Skeleton mesh
Full description
Migrated MorphoSource 1 Media File Title: Skeleton mesh Migrated MorphoSource 1 Media Group Title: CT scan of amnh-herpetology-a-78098, Asterophrys turpicola
Creator
--
Date created
--
Date uploaded
September 29, 2020

FILE OBJECT DETAILS Field Definitions

File name
Asterophrys-turpicola-AMNH78098_skel.stl
File format(s)
STL
File size
395 MB
Points
4128267
Polygons
8276131
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
45.923, 42.750, 49.172
Centroid coordinates
-0.408, 0.424, -6.648
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
originally appearing in , the collection of which was funded by
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Herpetology:A-78098 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.2
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
2200
Voltage
70
Power
0.014
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived private media that exists on MorphoSource but is inaccessible with current user permissions.

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Private media inaccessible with current permissions

STEP 3: IMAGE PROCESSING

Derived private media was processed to create derived Media 000162129: Element Unspecified [Mesh] [Etc] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000162129: Element Unspecified [Mesh] [Etc] (this media)