Media 000162907: Raw Data
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000162907
Media type
Volumetric Image Series
Object element or part
Raw data
Object represented
Object taxonomy
Chiasmocleis sp.
Side
--
Orientation
--
Short description
CT scan slice
Full description
Migrated MorphoSource 1 Media File Title: CT scan slice Migrated MorphoSource 1 Media Group Title: Chiasmocleis haddadi Migrated MorphoSource 1 Media Group Description: Specimen scanned at the AMNH with a GE phoenix v|tome|x s240
Creator
--
Date created
--
Date uploaded
October 01, 2020

FILE OBJECT DETAILS Field Definitions

File name
MNHN_ra_2011_139.zip
File format(s)
ZIP archive, TIFF
File size
815 MB
Image width
737
Image height
445
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.025091
Y pixel spacing
0.025091
Z pixel spacing
0.025091
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,660

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Unknown Make Unknown CT Scanner, No Organization (No Institution)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object MNHN:RA:2011.139 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Unknown Make Unknown CT Scanner
Device facility
No Organization (No Institution)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
150
Power
--
Amperage
160
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000162907: Raw Data [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000162907: Raw Data [CTImageSeries] [CT] (this media)