Media 000162961: Whole Body [Mesh] [Etc]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000162961
Media type
Mesh
Object element or part
whole body
Side
--
Orientation
--
Short description
Skeleton mesh
Full description
Migrated MorphoSource 1 Media File Title: Skeleton mesh Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
October 01, 2020

FILE OBJECT DETAILS

File format(s)
application/stl
File size
360 MB
Points
959,080
Polygons
1,922,351
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
30.327, 66.635, 79.308
Centroid coordinates
1.610, 3.197, -5.501
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Open Download
IP holder
Florida Museum of Natural History, University of Florida
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714; oVert TCN
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: University of Florida provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:herp:31694 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
2040
Voltage
120
Power
0.024
Amperage
200
Surrounding material
None
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000078242: Whole Body [CTImageSeries] [Etc] .

Processing Details

Creator
Zachary Randall
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000078242: Whole Body [CTImageSeries] [Etc] was processed to create derived Media 000162961: Whole Body [Mesh] [Etc] (this media).

Processing Details

Creator
Zachary Randall
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000162961: Whole Body [Mesh] [Etc] (this media)