Media 000164724: Ear
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000164724
Media type
Volumetric Image Series
Object element or part
ear
Object represented
Object taxonomy
Tachyglossus aculeatus
Side
--
Orientation
--
Short description
HRXCT scan - Ear
Full description
University of Texas High-Resolution X-ray CT Facility Archive Rowe: tachyear: Scans of the ear of Tachyglossus aculeatus (TMM M-1826) for Timothy Rowe of The University of Texas at Austin. Specimen scanned by Matthew Colbert 16 October 2014. 16bit: Scan parameters: NSI scanner. Feinfocus source, high power, 200 kV, 0.11 mA, one aluminum filter, Perkin Elmer detector, 0.25 pF gain, 1 fps (499.893 ms integration time), no binning, no flip, source to object 133.542 mm, source to detector 1298.57 mm, continuous CT scan, no frames averaged, 0 skip frames, 3600 projections, 6 gain calibrations, 5 mm calibration phantom, data range [-5, 35] (rescaled from NSI default), beam-hardening correction = 0.1. Voxel size = 0.0111 mm. Total slices = 1493.
Creator
Matthew Colbert
Date created
October 16, 2014
Date uploaded
October 09, 2020

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
3.89 GB
Image width
1425
Image height
1057
Color space
BlackIsZero
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.011100
Y pixel spacing
0.011100
Z pixel spacing
0.011100
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,493

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas Memorial Museum
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
oUTCT provided access to these data, with data collection funded by Tim Rowe and data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:M:1826 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
none
Projections
3600
Voltage
200
Power
--
Amperage
110
Surrounding material
0.25 pF gain
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000164724: Ear [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000164724: Ear [CTImageSeries] [CT] (this media)