Media 000165540: Foot
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000165540
Media type
Volumetric Image Series
Object element or part
Foot
Object represented
Object taxonomy
Varecia variegata rubra
Object organization
Side
Right
Orientation
--
Short description
Zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: Zipped tiff stack Migrated MorphoSource 1 Media Group Title: Foot Migrated MorphoSource 1 Media Group Description: correct chirality
Creator
--
Date created
--
Date uploaded
October 19, 2020

FILE OBJECT DETAILS Field Definitions

File name
DLC_6311f_Varecia_rubra_R_foot.zip
File format(s)
ZIP archive, TIFF
File size
2.14 GB
Image width
1474
Image height
840
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.068490
Y pixel spacing
0.068490
Z pixel spacing
0.068490
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
906

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Duke Lemur Center
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dlc:6311f was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.354
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
2
Projections
2000
Voltage
155
Power
--
Amperage
160
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000165540: Foot [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Gabriel Yapuncich
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000165540: Foot [CTImageSeries] [CT] (this media)