Media 000165902: Whole Body [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000165902
Media type
CTImageSeries
Object element or part
whole body
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
October 27, 2020

FILE OBJECT DETAILS

File format(s)
image/tiff
File size
1.9 GB
Image width
521
Image height
1238
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.037451
Y pixel spacing
0.037451
Z pixel spacing
0.037451
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,785

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
IP holder
Museum of Vertebrate Zoology, UC Berkeley
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701797; NSF DBI-1701714; oVert TCN
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: University of California-Berkeley provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mvz:amphibian and reptile specimens:mvz:herp:251787 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.200098
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1560
Voltage
80
Power
0.016
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000165902: Whole Body [CTImageSeries] [CT] (this media).

Processing Details

Creator
Zachary Randall
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000165902: Whole Body [CTImageSeries] [CT] (this media)