Media 000166156: Partial Cranium
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000166156
Media type
Volumetric Image Series
Object element or part
Partial cranium
Object represented
Object taxonomy
Quercygale angustidens
Object organization
Side
NotApplicable
Orientation
--
Short description
MicroCT Image stack
Full description
Migrated MorphoSource 1 Media File Title: MicroCT Image stack Migrated MorphoSource 1 Media Group Title: MicroCT scan of partial cranium and derivative files
Creator
--
Date created
--
Date uploaded
October 30, 2020

FILE OBJECT DETAILS Field Definitions

File name
NRM-PZ-M2329_160kV_62.5uA_0.023mm.zip
File format(s)
ZIP archive, TIFF
File size
3.02 GB
Image width
1002
Image height
1023
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.046000
Y pixel spacing
0.046000
Z pixel spacing
0.046000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,433

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa x-ray microscope (xrm), Stockholm University Brain Imaging Centre (SUBIC) (Stockholm University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
--
IP holder
Swedish Museum of Natural History
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Data acquisition supported by a grant to the Stockholm University Brain Imaging Centre (SU FV-5.1.2-1035-15)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Therese Flink and Lars Werdelin provided access to these dataoriginally appearing in Flink et al. 2021 with data collection funded by SU FV-5.1.2-1035-15. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nrm:pz:m2329 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa x-ray microscope (xrm)
Device facility
Stockholm University Brain Imaging Centre (SUBIC) (Stockholm University)
Creator
Tunhe Zhou
Event date
February 02, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
160
Power
--
Amperage
62.5
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000166156: Partial Cranium [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Tunhe Zhou
Event date
February 02, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000166156: Partial Cranium [CTImageSeries] [CT] (this media)