Media 000166784: Body [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

Interactive/Embeddable Media Preview is currently unavailable. Please check back later.

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000166784
Media type
CTImageSeries
File format(s)
application/zip
File size
1,754,513,408 bytes
Object element or part
body
Side
--
Orientation
--
Short description
zipped bmp stack
Full description
Migrated MorphoSource 1 Media File Title: zipped bmp stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives Migrated MorphoSource 1 Media Group Description: Specimen Scan Symbol is N
Creator
--
Date created
--
Date uploaded
November 13, 2020
Image width
--
Image height
--
Color space
--
Color depth
--
Compression
--
X pixel spacing
0.0355312
Y pixel spacing
0.0355312
Z pixel spacing
0.0355312
Pixel spacing units
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
--
IP holder
Oregon State Ichthyology Collection
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701714; oVert TCN; NSF DBI-1701665
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Oregon State Ichthyology Collection provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object os:fishes:6514 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Jules Chabain and Tess Peixoto
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
1.175
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
4
Projections
800
Voltage
65
Power
0.008
Amperage
123
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000166784: Body [CTImageSeries] [CT] (this media).

Processing Details

Creator
Jules Chabain and Tess Peixoto
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000166784: Body [CTImageSeries] [CT] (this media)