Media 000168054: Element Unspecified [Mesh] [CT]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000168054
Media type
Mesh
File format(s)
text/prs.wavefront-obj
File size
183,052,942 bytes
Object element or part
--
Side
--
Orientation
--
Short description
3D mesh (OBJ) with vertex color
Full description
Migrated MorphoSource 1 Media File Title: 3D mesh (OBJ) with vertex color Migrated MorphoSource 1 Media Group Title: MicroCT volume and derivatives of uf:herp:28219, Varanus komodoensis
Creator
--
Date created
--
Date uploaded
December 09, 2020
Points
957,532
Polygons
2,001,107
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
34.225, 33.76, 87.884
Centroid coordinates
8.079, -11.221, 24.193
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
--
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701714; oVert TCN
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object uf:herp:28219 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.2
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
3
Projections
1300
Voltage
100
Power
0.02
Amperage
200
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000168055: Element Unspecified [CTImageSeries] [CT] .

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000168055: Element Unspecified [CTImageSeries] [CT] was processed to create derived Media 000168054: Element Unspecified [Mesh] [CT] (this media).

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000168054: Element Unspecified [Mesh] [CT] (this media)