Media 000168753: Skull [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

Interactive/Embeddable Media Preview is currently unavailable. Please check back later.

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000168753
Media type
CTImageSeries
File format(s)
inode/x-empty
File size
99,612,894 bytes
Object element or part
skull
Side
--
Orientation
--
Short description
--
Full description
Migrated MorphoSource 1 Media Group Title: HRXCT scan Migrated MorphoSource 1 Media File Description: University of Texas High-Resolution X-ray CT Facility Archive 0079\\r\\n\\r\\nBell/cteno\\r\\n\\r\\nScans of Ctenosaura, the Mexican Spinytail Iguana (no data - pet death
Creator
--
Date created
--
Date uploaded
December 14, 2020
Image width
--
Image height
--
Color space
--
Color depth
Compression
--
X pixel spacing
0.087
Y pixel spacing
0.087
Z pixel spacing
0.155
Pixel spacing units
Mm
Number of images in set
482

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
--
Funding attribution
DBI-1902242
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: Chris Bell provided access to these data , with data upload to MorphoSource funded by DBI-1902242. The files were downloaded from www.MorphoSource.org, Duke University.
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object l-cb was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Richard Ketcham and Matthew Colbert
Date
--
Software
--
Description
--
Description attachment
None
Photographic reference
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
2
Projections
1800
Voltage
120
Power
--
Amperage
200
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000168753: Skull [CTImageSeries] [CT] (this media).

Processing Details

Creator
Richard Ketcham and Matthew Colbert
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000168753: Skull [CTImageSeries] [CT] (this media)